Skip to main content
Menu
US
Cell Counting and Image Cytometry

Obtaining a Direct Cell Count

Section
Celigo Applications
Celigo Applications
Cell Counting Method Selection
Cell Counting and Image Cytometry FAQs
Cell-based Assays for Bioprocessing
Cell-based Assays for Gene Therapy Development
Cellometer Applications
Modern Virology Assays
Sub Section
Celigo Image Cytometer Direct Cell Counting Assays for Immunotherapy
3D Cell Models
Assays for Virology Research
Brightfield Applications
Celigo Cell Counting Applications
Celigo Fluorescent Assays
Celigo Image Cytometer Direct Cell Counting Assays for Immunotherapy
Cell Line Development
Migration and Invasion Assays
iPSC Reprogramming
Topic
Obtaining a Direct Cell Count
Complement-Dependent Cytotoxicity
Antibody-dependent Cell-mediated Cytotoxicity
CAR-T Mediated Toxicity
Direct NK Cell Killing
Obtaining a Direct Cell Count
Using The Gating Interface
Whole Well Imaging

Determining a direct cell count of tumor cells during live cell analysis of various Immuno-oncology assays

  1. Directly image cells within a well
  2. Perform non-invasive, non-toxic, non-radioactive ADCC based assays
  3. Acquire direct cell counts per well and export all data as a .CSV file

Obtain a direct cell count using the Celigo image cytometer

The Celigo image cytometer is a plate-based cytometer developed for live cell analysis of immune cells. These functional assays scan the entire well of standard microplates and capture brightfield and fluorescent images. The captured images are analyzed with the Celigo software to measure size, morphology, direct cell count, confluence, and fluorescent intensity. The measured parameters are used to generate cell proliferation kinetic data, GFP/RFP expression, tumor spheroid size change, DNA cell cycle analysis, apoptosis, ADCC and CDC cytotoxicity results.

Using Calcein AM to obtain a direct cell count

Celigo with plate
  • Uses Celigo to capture and analyze brightfield and green fluorescent images
  • Target suspension and adherent cells are stained with Calcein AM and then mixed with the effector cells
  • A direct cell count of target cells (Calcein+) is done and monitored over time
  • Reduction in target cell number indicates cell-mediated or antibody-dependent cell-mediated cytotoxicity
Tumor T cell whole well image

For each well, Celigo image cytometer produces high-resolution whole well images for 96-, 384- and1536-well plates.

Celigo image cytometry for direct cell counting in immuno-oncology

Green calcein am stained target cells

Imaged tumor cells stained with Calcein AM

Green Calcein AM stained target cells

Outlined counted live target cells

Counted Calcein positive (+) live tumor cells

Outlined counted live target cells


Live cell analysis of immune cells include cytolytic cells: CIK cells, NK cells, Neutrophils and CAR-T cells.

Various fluorescent probes and stains were used to identify the target cells and thereby monitor cell killing. They include fluorescent proteins – GFP, RFP, Calcein AM, Cell tracer dyes CFSE, CellTraceTM dyes and viability dyes – PI, DAPI.

Perform a direct cell count by staining target cells with Calcein AM and using the Celigo image cytometer

 

Detection method Description Existing issues
Radioactivity release Measure the release or radiolabels, 51Cr, 101In in the supernatant Handling hazardous material; Indirect measurement of cell death
Fluorescence release Measure the release of Calcein AM fluorescent molecules in the supernatant Indirect measurement of cell death; Endpoint assay only
LDH release Measure the release of cytosolic enzyme in the supernatant Indirect measurement of cell death; Endpoint assay only
Luciferase reporter assay Measure luciferase as the cells die Indirect measurement of cell death
Flow cytometry Measure the number of viable cells and viability in the sample Cannot perform in plates; Must trypsinize for adherent cells

 

Cytotoxicity assays play a central role in studying the function of immune effector cells such as cytolytic T lymphocytes (CTL) and natural killer (NK) cells. Traditionally, cytotoxicity assays have been performed using Chromium-51 (51Cr) and Calcein release assays.

The assays involve labeling tumor cells (target) with a radioisotope or fluorescent dyes. When the target cells are subjected to CTLs or NK cells (effector) mediated killing, they release the entrapped labels into the media. The amount of released label in the media is measured to determine the level of cytotoxicity the effectors have induced.

Live tumor cells at multiple time points

A live cell analysis of cytotoxicity assay using the Celigo image cytometer for direct cell counting of fluorescently labeled target cells has recently been introduced.

Cell images are used by the Celigo software to obtain a direct cell count of tumor cells for each well over multiple time points.

The same plate was imaged over a 160 minute period to monitor the killing of Calcein AM stained tumor target cells by the immune effector cells.

Direct cell counts in plate format

Direct cell counts for each well are reported in the plate map format and counts per well are displayed as a plate map format for easy review.

Numerical data per well

Numerical data per well can be exported to excel as a CSV file. Export all data to Excel. Exported data maintains plate map format within excel for easy data processing


For research use only. Not for use in diagnostic procedures.

ON THIS PAGE