Test Code | D9999 |
---|---|
Test Summary |
Diagnostic whole exome analysis and interpretation of a proband performed after a qualifying AnyPanel or pre-curated panel test. |
Turn Around Time | 3 - 5 weeks |
Acceptable Sample Types | Reanalysis Only |
Acceptable Billing Types | Institutional Billing , Self (patient) Payment |
NY Approved | No |
Self (patient) Price | $900.00 |
Institutional Price | $1,200.00 |
This test involves a whole exome analysis and interpretation of previously generated data from a qualified Revvity Omics panel test. All analysis is performed utilizing next-generation sequencing (NGS) technology. All variants are classified according to American College of Genetics and Genomics (ACMG) guidelines. It is recommended that any updated clinical notes and phenotypes are provided to aid in the analysis.
FASTQ files from a previous exome-based sequencing test previously completed at Revvity Omics are utilized. A base is considered to have sufficient coverage at 20X and an exon is considered fully covered if all coding bases plus three nucleotides of flanking sequence on either side are covered at 20X or more. A list of these regions, if any, is available upon request. Alignment to the human reference genome (GRCh37) is performed and annotated variants are identified in the targeted region. Variants reviewed have a minimum coverage of 8X and an alternate allele frequency of 20% or higher. Indel and single nucleotide variants (SNVs) may be confirmed by Sanger sequence analysis before reporting at director discretion. This assay cannot detect variants in regions of the exome that are not covered, such as deep intronic, promoter and enhancer regions, areas containing large numbers of tandem repeats, and variants in mitochondrial DNA. Copy number variation (CNV) analysis detects deletions and duplications; in some instances, due to the size of the exons, sequence complexity, or other factors, not all CNVs may be analyzed or may be difficult to detect. When reported, copy number variant size is approximate. Actual breakpoint locations may lie outside of the targeted regions. CNV analysis will not detect tandem repeats, balanced alterations (reciprocal translocations, Robertsonian translocations, inversions, and balanced insertions), methylation abnormalities, triploidy, and genomic imbalances in segmentally duplicated regions. This assay is not designed to detect mosaicism; possible cases of mosaicism may be investigated at the discretion of the laboratory director. Primary data analysis is performed using Illumina bcl2fastq converter v2.19. Secondary analysis is performed using Illumina DRAGEN Bio-IT Platform v.3.10.8. Tertiary data analysis is performed using SnpEff v5.0 and Revvity Omics’ internal ODIN v.1.01 software. CNV and absence of heterozygosity are assessed using BioDiscovery’s NxClinical v6.1 software.
Collection | This test is performed on data that has already been generated by Revvity Omics. |
---|---|
Sample Condition | N/A |
Shipping | N/A |