The NEXTFLEX® Poly(A) Beads 2.0 kit offers a convenient method for the purification of pure, intact mRNA upstream of RNA-Seq library prep with improved mRNA yields, low rRNA contamination, and a simple protocol.
For research use only. Not for use in diagnostic procedures.
Feature | Specification |
---|---|
Automation Compatible | Yes |
Product Group | mRNA Enrichment |
The NEXTFLEX® Poly(A) Beads 2.0 kit offers a convenient method for the purification of pure, intact mRNA upstream of RNA-Seq library prep with improved mRNA yields, low rRNA contamination, and a simple protocol.
For research use only. Not for use in diagnostic procedures.
Poly(A)-tailed mRNA is isolated via magnetic beads conjugated to oligo(dT), and separation using a magnetic stand allows for high mRNA recovery. The intact mRNA is eluted in small volumes, thereby eliminating the need for precipitation. These beads have been tested with the NEXTFLEX® Rapid Directional RNA-Seq Kit 2.0.
Several approaches have been used to remove ribosomal RNA (rRNA) from total RNA samples for RNA-Seq library preparation. Removal of rRNA avoids the waste of reagents and bioinformatics resources to sequence and align ~85% of total RNA comprising rRNA (which is generally not a target of interest in NGS sequencing experiments). Revvity’s NEXTFLEX Poly(A) beads 2.0 kit offers an easy and cost-effective method for removing rRNA in RNA-Seq libraries. This product takes advantage of the tract of adenosine residues present at the 3’ ends of a vast majority of protein-coding mRNAs. Hybridization of these poly(A) tails to tracts of complementary thymidines (“oligo dT”) immobilized on solid supports allows the retrieval of poly(A)+ RNAs by recovering the solid support along with the hybridized RNA complexes.
Figure 1. Example of 1 µg of Universal Human Reference RNA (Agilent® # 740000) after mRNA enrichment using the NEXTFLEX Poly(A) Beads 2.0. 3 µL Poly(A) enriched RNA was run on the LabChip® GX Touch™ HT Nucleic Acid Analyzer using the RNA Pico Assay Reagent Kit (# CLS960012) and a DNA/RNA/Charge Variant Assay LabChip (# 760435)
(A) mouse brain
(B) MCF7 cells
Figure 2. NEXTFLEX Poly(A) Beads 2.0 yield clean mRNA with minimal rRNA carry-over from 5 µg of total RNA input from (A) mouse brain and (B) MCF7 cells. ~1.5% rRNA carry-over was observed based on sequencing data.
For total RNA-Seq solution not limited to only mRNA-Seq, Revvity offers the NEXTFLEX RiboNaut™ rRNA depletion kit (Human / Mouse / Rat) for use NEXTFLEX Rapid Directional RNA-Seq Kit 2.0 or other applications.
Automation Compatible |
Yes
|
---|---|
Format |
Automation Friendly Volumes
|
Product Group |
mRNA Enrichment
|
Shipping Conditions |
Shipped Ambient
|
Unit Size |
48 rxns
|
Are you looking for resources, click on the resource type to explore further.
This flyer describes the benefits of the NEXTFLEX® Rapid Directional RNA-seq 2.0 Kit.
We are here to answer your questions.